BCH Energy
Capacity: 2.00 nos. trains each rated at 213,600.00 gallons between regeneration
Location: North Carolina – USA
Type: Demineralized Water Treatment w/ Pre-Treatment Clarification & Filtration
Application: Boiler Demineralized Make Up Water System
Units Involved: EMCO supplied a counter-current regenerated demineralizer system consisting of two trains each having a cation and anion. A common de-carbonator is also included.
Each train produces 213,600 gallons between regeneration @ 178 gpm. Effluent water quality from this plant is silica <0.02 ppm and conductivity is <0.50 μOhms.
EMCO has supplied a solids contact clarifier; three shop assembled gravity filters, the acid/caustic pumps and mixing stations, bulk acid/caustic storage tanks, the clarifier chemical feed skids and storage tanks, and a plc-based control system.
The engineer on this project was “Lockwood Greene” – Atlanta – GA